| Sign In | Join Free | My entremaqueros.com |
|
Brand Name : Fluke
Model Number : 376 FC
Certification : CE
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Range : 2500 A
Resolution : 0.1 A
Accuracy : 3% ±5 Digits (5 – 500 Hz)
Highlight : 2500 A Range Clamp Meter, 0.1 A Resolution Clamp Meter
Fluke 376 FC True-RMS Clamp Meter
| General Specifications | ||||||
| AC Current via Jaw | ||||||
| Range | 999.9 A | |||||
| Resolution | 0.1 A | |||||
| Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | |||||
| 2.5% ±5 digits (100-500 Hz) | ||||||
| Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | |||||
| 2.5 @ 600 A | ||||||
| Add 2% for C.F. >2 | ||||||
| AC Current via Flexible Current Probe | ||||||
| Range | 2500 A | |||||
| Resolution | 0.1 A (≤ 600 A) | |||||
| 1 A (≤ 2500 A) | ||||||
| Accuracy | 3% ±5 digits (5 – 500 Hz) | |||||
| Crest Factor (50/60Hz) | 3.0 at 1100 A | |||||
| 2.5 at 1400 A | ||||||
| 1.42 at 2500 A | ||||||
| Add 2% for C.F. > 2 | ||||||
| i2500-10 Flex | i2500-18 Flex | i2500-36 Flex | ||||
| A | ||||||
| Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | 4.8 in (122.2 mm) | |||
| Error | ±0.5 % | ±0.5 % | ±0.5 % | |||
| B | ||||||
| Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | 5.3 in (133.6 mm) | |||
| Error | ±1.0 % | ±1.0 % | ±1.0 % | |||
| C | ||||||
| Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | 5.8 in (147.6 mm) | |||
| Error | ±2.0 % | ±2.0 % | ±2.0 % | |||
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||||
| DC Current | ||||||
| Range | 999.9 A | |||||
| Resolution | 0.1 A | |||||
| Accuracy | 2% ±5 digits | |||||
| AC Voltage | ||||||
| Range | 1000 V | |||||
| Resolution | 0.1 V (≤600.0 V) | |||||
| 1 V (≤1000 V) | ||||||
| Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | |||||
| DC Voltage | ||||||
| Range | 1000 V | |||||
| Resolution | 0.1 V (≤600.0 V) | |||||
| 1 V (≤1000 V) | ||||||
| Accuracy | 1% ±5 digits | |||||
| mV dc | ||||||
| Range | 500.0 mV | |||||
| Resolution | 0.1 mV | |||||
| Accuracy | 1% ±5 digits | |||||
| Frequency via Jaw | ||||||
| Range | 5.0 Hz to 500.0 Hz | |||||
| Resolution | 0.1 Hz | |||||
| Accuracy | 0.5% ±5 digits | |||||
| Trigger level | 5 Hz to 10 Hz, ≥10 A | |||||
| 10 Hz to 100 Hz, ≥5 A | ||||||
| 100 Hz to 500 Hz, ≥10 A | ||||||
| Frequency via Flexible Current Probe | ||||||
| Range | 5.0 Hz to 500.0 Hz | |||||
| Resolution | 0.1 Hz | |||||
| Accuracy | 0.5% ±5 digits | |||||
| Trigger level | 5 Hz to 20 Hz, ≥25 A | |||||
| 20 Hz to 100 Hz, ≥20 A | ||||||
| 100 Hz to 500 Hz, ≥25 A | ||||||
|
|
Fluke 376 FC True-RMS Clamp Meter Images |